Reliability
Continuous vs peak fingertip force: what 20 N hides
Continuous vs peak fingertip force: 6 of 10 hands here publish a force number, 3 call it a maximum, and none publishes a continuous rating.
The short version
Six of the ten hands in this index publish a fingertip force and none publishes a continuous rating. Three of the six label the figure a maximum. The servo under the cheapest 16-DOF hand is specified at stall torque, and its own manual says that rating is not the continuous one. Price per published newton runs from $138 to $2,400.
Almost every dexterous hand datasheet that carries a force figure carries a maximum. Six of the ten hands in this index publish one. Three of those six say so in the text, with the word max or the Chinese 最大. None of the ten publishes a continuous rating a buyer could design a shift around, which means continuous vs peak fingertip force is a distinction the category sells but does not document.
The gap is not academic. The cheapest 16-DOF hand with a published price, the LEAP Hand v1 kit at $2,066, is driven by 16 Dynamixel XC330-M288-T servos. The servo maker publishes one torque figure for that part, 0.93 N·m, and defines it at stall. The same page states that the stall rating is not the continuous output rating.
The two ratios in the table differ by 17 times. LEAP works out to $138 per published newton at the top of its 5–15 N range. The Unitree Dex5-1 publishes 10 N at $24,000, which is $2,400 per newton. Both numbers are accurate. They do not describe the same quantity, which is the whole problem with quoting either one in a purchase order.
| Hand | Actuated DOF | Published force | Basis as written | Price per highest published newton, USD or RMB, chart plots the USD rows |
|---|---|---|---|---|
| LEAP Hand v1 kit | 16 | 5–15 N | "configuration dependent" | $138 |
| Inspire RH56DFX | 6 | 15 N thumb, 10 N four-finger | 最大, maximum grip force | $373 |
| Allegro Hand V5 | 16 | 5–20 N | no basis stated | $650 |
| Unitree Dex5-1 | 16 | 10 N | "fingertip strength", no basis | $2,400 |
| LinkerBot O6 | 6 | 20 N thumb, 25 N four-finger | max | 156 RMB, Lite promo |
| PaXini DexH13 GEN2 | 13 | 15 N | max, vendor laboratory | 6,533 RMB |
| Shadow Dexterous Hand | 20 | 10 N | no basis stated | not computable, quote only |
| AGIBOT OmniHand 2025 | 10 | not published | — | not computable |
| Leadshine DH116S | 6 | not published | — | not computable |
| ORCA Hand | 17 | unconfirmed | — | not computable |
The last column divides the lowest published hand price by the highest published force. It is a ratio of two numbers, not a measure of quality, and it deliberately mixes grip force with fingertip force because the vendors do. That is the finding: the denominators are not the same quantity, so the ratio mostly measures how loose each spec is.
Is a 20 N fingertip force a continuous rating?
No hand in this index says that it is, and three of them say the opposite by using the word maximum. The LinkerBot O6 page lists a 20 N maximum thumb force, a 25 N maximum four-finger force and a 70 N five-finger grasp. Those are three different measurements on one page, and the top of the range is the number that gets copied into comparison tables.
Inspire's own product page is unusually explicit for this price bracket. It reads 拇指最大抓握力 15 N and 四指最大抓握力 10 N, which translates as maximum grip force, thumb and four fingers. Two things follow. The figure is a maximum, and it is a grip force rather than a fingertip force. This site's own record filed it under fingertip force, following the dealer pages that resell the hand, so the looseness sits in the channel copy too.
Unitree takes the third route and simply omits the qualifier. Its parameter table reads "Fingertip strength 10N" with no condition attached, while the load rows below it carry a full one. Those rows read "Palm Facing Down At Room Temperature, Grasping A 5cm Round Hard Object" with a maximum of 3.5 kg, and 4.5 kg palm sideways. Room temperature is the qualification on those load figures, and the force figure has none.
What does the servo underneath say?
On the LEAP v1 the answer is written by ROBOTIS, not by the hand vendor. The XC330-M288-T page lists a stall torque of 0.93 N·m at 5.0 V and 1.80 A, with a 288.35:1 gear ratio, and then adds a note that matters more than the number: the maximum torque measured on the performance graph is generally less than the maximum stall torque, and real-world performance is closer to the graph than to the rating.
The same page warns that sustained high current can damage the motor, and that an overheated servo should cool for 20 minutes or more. A hand that follows that instruction has a duty cycle, whether or not its datasheet admits one.
The arithmetic under the LEAP range is worth doing. Divide 0.93 N·m by 15 N and the implied lever arm is 62 mm. Divide it by 5 N and the implied lever arm is 186 mm. A finger does not change length by a factor of three, so the bottom of the published range cannot come from the same full-current condition as the top. Either the current is limited or the contact geometry differs, and the datasheet says neither.
How much force survives an eight-hour shift?
The two vendors that publish both a maximum and a static current give the clearest answer available. Unitree lists a maximum current of 4 A and a static current of 0.2 A, a ratio of 20. Inspire lists 2 A maximum and 0.09 A static, a ratio of 22. The top of the electrical range is a state the hand occupies for a fraction of a second, and the static figure is what it draws holding a pose.
That ratio cuts both ways, but the honest reading is narrower than "derate everything". A static pinch draws the static current, so a hand holding a part for hours is not the thermal problem it looks like. The heat is in repeated moves at high current: the grasp-release cycle that saturates the motor and then repeats. No vendor in this index publishes where that boundary sits, and the two who publish current publish the ceiling rather than the average.
What a buyer can do is price the uncertainty. A spare DH116S is from $2,299; a spare Dex5-1 is $24,000. On the Leadshine the force is not published at all, so the gamble is different: you buy a hand whose force you will discover during commissioning.
Which force number should go in an RFQ?
Write the requirement as a force held under stated conditions, then make the vendor commit to the conditions. The workable form is: newtons at a stated joint angle, against a stated contact area, for a stated hold time or cycle rate, with the current limit the firmware ships with. The RFQ template has fields for the first three; add the fourth by hand.
Three follow-up questions separate a datasheet from a specification. What is the continuous force at 50% duty? What does the controller do when the motor reaches its temperature warning, cut torque or latch an error? And what does one replacement finger cost, delivered? A vendor who answers all three is selling a component. A vendor who answers with one number is selling a number.
The peak figure still has a use. Seating a connector, pushing a latch, breaking a friction fit: those are impact tasks where the transient is the whole event, and the maximum is the correct specification. The mistake is carrying it into a task that looks similar but runs all day.
Where this breaks down
Three cases where it stops being useful.
A hand whose limit is structural rather than thermal does not derate the way a motor does. The O6's 50 kg load claim is the example: whatever that figure means, it is a structure talking, not a winding.
Very low duty work does not need the number. A lab running a few dozen grasps an afternoon will never find the thermal ceiling, and the deciding factors become software, sensing and how fast a replacement arrives.
And a static hold is not a continuous rating either, in the other direction. If your task is to clamp a part for six hours, the current draw is the static figure, and the hand may run cooler than a pick-and-place cell doing 10,000 cycles. "Continuous" describes a thermal state, not a duration.
The price-per-newton column is the weakest part of this piece, deliberately. It compares a grip force with a fingertip force, a maximum with a nominal, and an export price with a domestic one. It is published because no better cross-vendor number exists, and the spread is itself the evidence that the spec is not standardized. The price index keeps the raw observations with their channels and dates so the ratio can be recomputed when those change.
Buy on the force number only when the task is a peak task. For a shift-length job, buy from the vendor who will put a continuous figure and a thermal behavior in writing, and treat the rest as a peak with a price attached. If neither vendor will commit, buy two cheap hands instead of one expensive one, and keep the change. Most buyers specify 20 N because it is the biggest number on the page, and meet the real ceiling in week three. That ceiling echoes the dexterous hand tendon replacement record: the specification that decides the repair bill is the one nobody publishes.
Sources
- ROBOTIS, DYNAMIXEL XC330-M288-T e-Manual, stall torque, current and performance graph note, checked November 21, 2026. https://emanual.robotis.com/docs/en/dxl/x/xc330-m288/
- Unitree Robotics, Dex5-1 and Dex5-1P parameter table, fingertip strength, load conditions and current, checked November 21, 2026. https://www.unitree.com/Dex5-1
- Inspire Robots, RH56DFX series product page, maximum grip force, force resolution and current, checked November 21, 2026. https://www.inspire-robots.com/dexterous%20hands/rh56dfx-series/
- MechHand records for LEAP Hand, LinkerBot O6, PaXini DexH13 and Allegro V5, prices and force fields, checked November 21, 2026. https://mechhand.com/hands/leap-hand/
Questions
Is a peak fingertip force the same as a continuous one?
No. A peak figure describes a short condition at full current. A continuous figure describes what the hand can hold without the motor reaching its thermal limit. Of the ten hands in this index, none publishes the second number.
Can I use the published force figure to size a gripper task?
Only as an upper bound. The Unitree page states 10 N of fingertip strength and then rates its load at room temperature, palm down, on a 5 cm hard object, which is the level of qualification the force number itself does not carry.
What should I ask a vendor for instead?
Force at a stated joint angle and contact area, held for a stated time, plus the current limit the firmware ships with and what the hand does when it overheats. If the answer is a single number with no conditions, treat it as a peak.
Does a long static hold damage the hand?
Probably not on the motors, because a static hold draws the static current, which is 0.09 A on the Inspire RH56DFX and 0.2 A on the Unitree Dex5-1. The heat comes from repeated moves at high current, not from holding still.