Integration
LEAP hand Franka Panda: 50 mm, 1.2 kg, 40% of payload
LEAP hand Franka Panda mounting is a 50 mm bolt circle, a 1.2 kg hand taking 40% of a 3 kg payload, and an adapter plate neither vendor lists.
The short version
The Panda's flange is a 50 mm bolt circle and its payload is 3 kg. The LEAP v1 weighs 1.2 kg, so the hand takes 40% of that payload and a pair takes 80%. Neither vendor publishes the adapter plate; the only combined model we found is a lab repository with a lab-only warning.
The LEAP hand Franka Panda pairing rests on two published numbers and one part that neither vendor supplies. Franka's datasheet gives the mounting flange as DIN ISO 9409-1-A50, a 50 mm bolt circle, and the payload as 3 kg. The LEAP Hand v1 lists at $2,066, weighs 1.2 kg, and so takes 40% of that payload before an adapter plate, a camera or an object is added.
The missing part is the plate. The hand project releases CAD and a hand-only URDF. Franka publishes the flange and a 1 kHz control interface. The only model we found that puts this arm and this hand on one kinematic tree sits in a university retargeting repository, and its hardware section opens with a notice that the setup may only work on that lab's arm.
Three LEAP configurations, priced from the dealer listing this site tracks, against the arm figure from the datasheet:
| Configuration at the flange | Mass at the flange | Share of the 3 kg payload | Price, USD, one dealer listing, checked November 2026 |
|---|---|---|---|
| LEAP Hand v1 kit | 1.2 kg | 40% | $2,066 |
| LEAP Hand v2 | 0.5 kg | 17% | $4,550 |
| LEAP Hand v1, two hands | 2.4 kg | 80% | $4,133 |
| Franka Panda arm, for reference | 12.8 kg moving mass | not applicable | not published |
Payload share is the recorded hand mass divided by the arm's datasheet payload, a ratio of two published numbers rather than a test result. It belongs first in the order of questions because the arm does not care how much the hand can lift. The LEAP Hand record keeps the mass and the channel prices with their dates, and the price record keeps the three listings separate rather than averaging them.
Does a LEAP hand bolt onto a Franka Panda flange?
The arm end is answered by one line in the datasheet: DIN ISO 9409-1-A50, which fixes a 50 mm bolt circle. The hand end is answered by geometry rather than a drawing. The hand's base is a printed part, and the project releases 3D CAD alongside the URDF, so the hand-side hole pattern exists as a solid model you can measure, not as a dimensioned sheet. That is enough to specify a plate and not enough to order one without measuring.
We found no adapter listed by the hand project or by Franka on November 22, 2026, which makes the plate a buyer-designed part in every build we could document. It carries a 50 mm pattern on the arm face and the hand's pattern on the other.
Two things follow for a purchase order. The first is mass: the plate lands on the same payload as the hand, so a 200 g plate turns a 40% share into 47%. The second is the license. The SDK README states code under MIT and CAD under CC BY-NC-SA, which is non-commercial use with attribution. A lab printing its own plate is inside that license. A company shipping an integrated arm-and-hand unit is not, unless it draws its own plate or obtains written terms.
The electrical side has the same shape. The SDK asks for 5 V into the hand and a micro-USB cable to the control PC, and the arm's flange passes neither. A cable runs down the arm from a bench supply, and it is a snag point at every wrist rotation.
How much of the 3 kg payload does the hand take?
Forty percent for the v1, 17% for the v2, and 80% for a pair. The pair leaves 0.6 kg for two plates, any added sensing and the object, which is why the bimanual kit is a two-arm purchase in practice and not a way to double the fingers on one wrist.
The 3 kg is a datasheet rating, not a measurement of your cell, and it is quoted at the flange. Anything outboard of the flange spends it, so a hand on a plate with a camera bracket is a different load case from the same hand bolted flat.
The second denominator is less quoted and more relevant to control. The arm's moving mass is 12.8 kg, so the v1 hand is 9.4% of the mass the joints accelerate and a pair is 19%. That number arrives as inertia in an impedance loop rather than as a payload line, and it changes the feel of a teleoperation session more than the payload figure does.
A third figure belongs in simulation. The URDF audit found the public LEAP model sums to 746 g against the 1.2 kg spec, which is 25% of payload rather than 40%. Gravity compensation tuned on that model meets hardware that is 454 g heavier than the controller expects.
Which rate does the hand run at on a Panda?
The arm runs its control loop at 1 kHz. The hand SDK quotes position queries, and position plus velocity plus current, at 500 Hz or less over USB, and notes that higher rates slow the bus. A policy written for the arm's rate sees hand state every other cycle; one written for the hand's rate leaves half the arm's bandwidth unused.
The repository that documents this pair makes the compromise visible. Before the retargeting node runs, it calls a step named franka_joint_states_freq_reduce, which lowers the arm's state frequency to what the hand side can consume. That is a workaround written by users, not a specification from a vendor.
The rest of the chain is three terminals and two ROS 2 workspaces: unlock the arm and activate the controller interface, launch a low-level joint impedance controller, bring up the hand, run the real-prep node. None of that appears in the hand's SDK or in the arm's datasheet.
Two settings need a look before anyone compares grip to a datasheet. The SDK ships the hand at a 300 mA current limit and documents raising it to 550 mA on a full hand, so the default build is not the strongest configuration. And the hand reports joint current rather than contact force, which matters when the task needs a force number rather than a motor reading.
Where the flange answer breaks down
Four cases where the arithmetic stops being the deciding factor.
A different arm. The published instructions are written around one Panda, with a controller launch file and a joint-state reducer tuned to it. Another 7-DOF arm needs its own stack, plate and frequency compromise. The plate geometry transfers; the bring-up does not.
Tactile work. The hand has no fingertip sensing, and the same repository pairs it with an external sensor in a model it calls panda_leap_tac3d. That sensor changes the fingertip geometry, the wiring and the mass budget, so the hand's share is the floor of the stack rather than the total.
Fast feedback. If the task needs hand state at the arm's rate, the USB and Dynamixel path is the ceiling, and more arm bandwidth does not fix it. Buyers who need tighter coupling are choosing a different interface, not a different hand.
A product, not a project. A kit with MIT code, non-commercial CAD and no mounting hardware is a research platform. Specifying it for a shipped product means taking on plate design, cable path, license review and support.
What to buy, and what to ask first
For a single Panda doing teleoperation or data collection on objects well under a kilogram, the v1 kit at $2,066 is the cheapest route to 16 independently driven joints, and 1.2 kg is a payload bill most labs can pay. Choose the v2 at $4,550 when wrist mass binds: 0.5 kg and 17% of payload buys back headroom, at the cost of eight motors and four joints that follow a tendon instead of moving on their own.
Do not buy a pair for one arm. At 80% of payload nothing is left for the object, and the second hand earns more on a second arm.
If you cannot machine or print a plate, or you need a vendor to own the assembly and its warranty, this is the wrong hand for the cell. Compare assembled hands with published mounting hardware on mass against the same 3 kg before comparing price; the LEAP against Allegro comparison shows how differently two 16-DOF hands sit on one arm.
Three questions settle the plate before the order goes out: the flange drawing with its tolerance, the plate's mass and material, and who owns the cable path at the wrist. The RFQ template has fields for the first two and a blank for the third. A shop that answers all three has quoted an integration. One that answers with a bolt circle has quoted a part.
Sources
- Franka Emika, Panda product manual, flange DIN ISO 9409-1-A50, payload 3 kg, moving mass 12.8 kg, 1 kHz control, checked November 22, 2026. https://download.franka.de/documents/100010_Product%20Manual%20Franka%20Emika%20Robot_10.21_EN.pdf
- LEAP Hand project page, assembly time and cost, released URDF and 3D CAD, checked November 22, 2026. https://leaphand.com
- LEAP Hand SDK README, 5 V and micro-USB setup, current limits 300 mA and 550 mA, 500 Hz query ceiling, MIT code and CC BY-NC-SA CAD, checked November 22, 2026. https://github.com/leap-hand/LEAP_Hand_API
- DexGrasp-TH retargeting repository, panda_leap_tac3d xacro, FCI bring-up and franka_joint_states_freq_reduce, lab-only notice, checked November 22, 2026. https://github.com/DexGrasp-TH/retargeting
- MechHand LEAP Hand record and URDF mass audit, checked November 22, 2026. https://mechhand.com/hands/leap-hand/
Questions
Will a LEAP Hand fit a Franka Panda without an adapter?
No. The Panda's mounting flange is DIN ISO 9409-1-A50, a 50 mm bolt circle. The LEAP Hand's base is a printed part with its own hole pattern, so the joint needs a plate with one pattern on each face. We found no such plate listed by the hand project or by Franka.
How much payload does the LEAP Hand leave on a Panda?
1.8 kg with the v1 hand, 2.5 kg with the v2, and 0.6 kg if you mount a pair. Those figures come from the 3 kg datasheet payload minus the recorded hand mass, before the adapter plate, a camera and the object.
Does the LEAP project ship a Franka mount or a combined URDF?
Not that we found on November 22, 2026. The project releases hand CAD and a hand-only model, and the SDK has no arm section. The combined Panda-plus-LEAP xacro we found sits in a university retargeting repository, and its hardware instructions may only work on that lab's arm.
Is the hand fast enough for a 1 kHz arm?
The arm runs at 1 kHz. The hand SDK quotes position and current queries at 500 Hz or less over USB, so a policy at the arm's rate sees hand state every other cycle. The lab repository that runs this pair inserts a node named franka_joint_states_freq_reduce to lower the arm's state rate instead.
Can I sell a product built on a LEAP Hand?
Read the two licenses first. The SDK README states code under MIT and CAD under CC BY-NC-SA, which is non-commercial with attribution. A lab that prints its own plate is inside that; a company shipping an integrated unit should design its own plate or get written terms.